Alerts and thresholds
On Cora Max: Alerts on Cora Max
You get an alert when a reading leaves the range you set for it. This page covers setting those ranges, what happens when an alert fires, and how long Cora waits before it says a device has stopped reporting.
To open the Alert Center, tap Alerts in the row of buttons under the dashboard. It's also in Settings → your tank → Alert thresholds.
The Alert Center
It has two tabs. Active lists the alerts that are up right now, with a count badge. Rules holds the rules that raise them.
Each active alert shows the parameter and tank, the reading that set it off, a short explanation, a severity chip, the kind of rule that fired (Threshold or Rate of Change) and when it fired. It has two buttons:
- View rule opens the rule behind it, so you can adjust the range. On a doser alert, such as a DŌS or ReefDose head running low or a missed dose, this button is Open doser instead. It opens that doser's page with its alerts.
- Explain this alert opens Cora Assistant with a question about the alert ready to send. Check it, change it if you like, then send it.
The Rules tab
Rules are grouped by parameter. Each rule has its own switch on its row, so you can turn one off without opening it. A row also shows Firing now while its alert is up, or when it last fired (or Never fired).
A dosing head's rules are named after the head and what they watch, for example Iodine · days left or Iodine · remaining. A missed dose shows up as Iodine · missed dose. Each DŌS and each ReefDose has one row of its own here, and its head alerts aren't listed one by one. Tap the row to open that doser's page. See Doser alerts.
At the bottom:
- Add recommended rules adds any of Cora's recommended rules that are missing. It skips a parameter that already has a rule. On a tank with no rules at all, this button reads Add Default Rules.
- Add Custom Rule sets up a rule of your own. Pick the parameter and the Rule type, Threshold or Rate of Change. The Add Rule button at the bottom right does the same.
Editing a rule
Tap a rule's row to open it. You'll find:
- Alert minimum and Alert maximum, the range itself. Leave one empty for a ceiling or a floor.
- Recommended, which puts Cora's suggested range back.
- Gauge Range (Cora display), with Gauge min and Gauge max. These only set the scale of the gauge on Cora Max. They never raise an alert.
- Cooldown between alerts, explained below.
- Enabled, and a delete button.
A device fault rule, such as a Trident out of reagent, has no range. You only choose its cooldown.
Setting a range
Parameters Cora can grade have a target range. The defaults come from your tank type and age when you set the tank up, and they're a sensible start. If a parameter has no usable range, Cora doesn't grade it, and its widget stays neutral grey.
The quickest way to change a range is to long-press the parameter's widget on the dashboard. That opens its thresholds. A normal tap opens the parameter view instead.
If the parameter has no rule yet, the fields start on Cora's default and a note underneath says so. Change any value to set your own.
You can set:
- a range, with a low and a high, for things like alkalinity or temperature
- a ceiling, with only a high, for things where low is fine, like nitrate or phosphate
- a floor, with only a low
What triggers an alert
An alert fires when a reading crosses a threshold. Cora checks each reading as it comes in, so one reading outside your range is enough.
A rate-of-change rule watches how fast a parameter moves instead of where it sits. Use it when the speed of a change matters more than the number.
Once an alert is up, it won't keep notifying you about the same thing. The rule's cooldown decides when it may notify you again.
Where alerts appear
- The bell, at the top right of the main tabs, keeps your history. The number shows how many you haven't read. More in Notifications.
- A push notification reaches your phone if that category is switched on.
- The widget on the dashboard turns amber or red.
- Cora Max shows the same alerts on its screen.
When equipment needs attention
Some alerts are about equipment, not a reading. When a device such as a Trident or a Jecod™ pump reports a fault, Cora sends a notification naming the tank and the device, for example "Display tank: Return pump needs attention". It also says what's wrong, such as a jammed rotor. When the fault clears, you get a second one: "Display tank: Return pump is OK again". Both fall under Equipment Faults in Settings → Notifications.
An AquaWiz™ KH Controller raises the same kind of alert, for every AquaWiz and without a Cora Max, when:
- its dosing pump reports a fault;
- its pH probe has failed, or is near the end of its life.
When the alkalinity supplement runs low, the alert uses the warning level you set on the controller. You can still change it in the Alert Center. A water box level that stays low or high for over an hour also raises an alert, but that needs the hourly reading from Cora Max (see Cora Max device pages): AquaWiz's 12-hourly cloud reading doesn't carry it.
A device has stopped reporting
When a connected device goes quiet, Cora sends "[Device]: stopped reporting". It doesn't mean the device is broken, only that Cora hasn't heard from it for a while. You get a second notification, "[Device]: reporting again", when it comes back.
How long Cora waits depends on the device:
| Device | Cora waits |
|---|---|
| Neptune™ Apex | About 30 minutes without an update |
| Red Sea™ ReefBeat | About 30 minutes |
| AquaWiz | About 25 hours, because AquaWiz lets Cora read its cloud only every 12 hours |
| Jecod pumps | Three missed readings in a row, on the pump's reading interval (90 minutes at the default 30) |
| Zigbee smart plug | Still silent 30 minutes after its hub restarted. Give it a name with Rename so the alert says which plug |
What to check depends on how Cora reads the device.
- Apex, ReefBeat and Jecod are read by a Cora Max over Wi-Fi. Check the device's power and Wi-Fi, and that the Cora Max that reads it is switched on and online.
- AquaWiz is read through your account with the maker. Check the account connection on the device's page in Cora Mobile.
These notifications fall under Equipment Faults in Settings → Notifications.
A Red Sea tank can also show a banner, "Red Sea readings have stopped updating", when no phone or Cora Max is reading its ReefBeat equipment. Tap it to pick a Primary Cora Max. The full fix is in Troubleshooting.
Choosing what reaches you
In Settings → Notifications you choose which categories can send you a push. See Notifications, which also covers keeping nights quiet.
Reef Buddy has no switch of its own. Its timing is the Briefing time row, just below Notifications in Settings. On the free plan there's no briefing notification.
Cooldowns: how often the same alert may notify you
Each rule has its own Cooldown between alerts. You set it when you add or edit the rule. A rule that never had one uses 1 h.
The cooldown doesn't hide the alert. It only limits how often Cora pushes about it. The reading is still graded, and the alert stays on the widget and under the bell the whole time.
You can pick 15 min, 30 min, 1 h, 2 h, 4 h, 8 h, 1 day, 3 days or 1 week.
A short cooldown suits a fast-moving reading like temperature. A long one, up to a week, suits something that stays wrong for days while you wait for a part, such as a Trident out of reagent or an empty dosing container.
Clearing an alert
An alert clears on its own when the reading comes back into range. There's nothing to dismiss. You get one notification when it does, for example "Display tank: Alkalinity recovered". If the problem comes back later, you get a new alert.
Sometimes the reading is wrong and the tank is fine, for example when a probe needs calibrating. Fix the source in that case. If you widen a threshold to silence a bad probe, you'll miss the next real problem too.
Turning an alert off
Turn off the switch on the rule's row in the Rules tab. Cora keeps the rule and its range, so you can switch it back on without setting it up again.
While a rule is off, Cora doesn't grade that reading. Its widget stays neutral grey and it never raises an alert.
Written for Cora Max 0.28.329 and Cora Mobile 1.4.30. Last checked 2026-10-24.