ICP and health reports
On Cora Max: Reef Buddy and reports
The Intelligence tab is where your lab results and long-term reports live. Pick a tank at the top first. Everything on the screen belongs to that tank.
Uploading an ICP test
Cora reads the PDF report your lab sends you. Download it from your lab's email or website first. Photos, scans and screenshots can't be read.
- Tap Upload ICP.
- Pick your lab, or leave it on Auto: detect the lab. Cora has tips for ATI, Fauna Marin, Modern Reef, Oceamo, Reef Zlements and Triton.
- Say what the sample is: Aquarium water, RO/DI water, Salt mix or Other. Only aquarium water updates your dashboard and alerts.
- Check the date the sample was taken. Labs print the date they analysed it, so Cora asks for yours and charts the results against it.
- Tap Choose PDF and pick the file.
It usually takes one to two minutes. Keep the screen open and the report opens as soon as it's ready. You don't have to type anything.
You can also email the PDF to icp@in.coraiq.tech. Send it from your sign-in email or a verified lab email (see below), and it arrives like a result from a lab.
If you upload the same report twice, Cora shows you the one you already have and doesn't charge you again.
Which email a lab can use
A lab or an emailed result finds your account by the email address it knows. That is your sign-in email, plus any lab email you add under Settings → your account card (Account & Subscription) → Lab & ICP emails.
- Tap Add lab email and type the address your lab uses.
- Tap Send code. Cora sends a 6-digit code to that address. It expires in 10 minutes.
- Enter the code and tap Verify. If you didn't get it, tap Resend code.
You can add up to 3 lab emails. Each shows Verified or Waiting for code, and Remove takes one off. After that, results sent to it no longer reach your account. An address that already belongs to another Cora account can't be added.
If you signed in with a hidden Apple email, labs can't find your account. The ICP screen shows a card, Get lab results automatically, that takes you to this setting. When you sign in with Apple, choose Share My Email to avoid the problem.
Send to Cora: results a lab or an email delivers for you
Some labs can send a result straight to Cora, and an ICP PDF you email in arrives the same way. You don't have to upload anything yourself.
If you have one tank, a result from a lab you trust, or one you emailed in, goes straight to that tank. With more than one tank, you'll see a banner: "Lab result from {lab} is waiting." Tap Choose tank and pick the tank it belongs to. Cora can't work that out on its own.
The report shows Sent by {lab} near the top, or Received by email, so you can tell it from one you uploaded.
If Allow Cora Assistant to use saved tank data is off, the result waits with the message Cora Assistant needs your OK to read it. Give your OK and it comes in.
The first result from a new lab
The first time a lab sends you a result, Cora asks you to approve it before adding it anywhere, even if you only have one tank. You'll see who sent it and can tick Trust this lab to skip this check next time a result comes from them.
Tap Approve to bring it in, or Decline to delete it without adding it to any tank.
Trusted labs and what labs can see
Settings → Cora Assistant → Trusted labs lists every lab you've trusted. The list shows up once you've trusted at least one. Revoke removes a lab, so its next result needs your approval again.
Share Cora's analysis with labs, on the same screen, decides what a lab sees after it sends you a result. On, it can see Cora's scores and written analysis. Off, it only sees that the result was delivered. It's off until you turn it on. The same switch also shows on a report a lab sent you.
If something here doesn't work, see Troubleshooting.
What you get back
You get a score out of 100 and a plain-language summary of what it means for your system, taking in your tank type, its age and your livestock.
The score compares your results with their target ranges, including any ranges you've set yourself. If any result is outside its range, the score can't go above 70, so it can't read Healthy. If one is far outside, it can't go above 40, however good the rest are. The label under the score reads Healthy from 71 to 100, Needs Attention from 40 to 70 and Critical from 0 to 39. Health Reports are scored the same way.
Every element is tracked, including trace elements and contaminants as well as the main parameters. Cora records every element and contaminant a lab can report, and the line some labs call Acidity is pH.
On each element row you'll see the range the lab printed, shown as Lab range, next to Cora's own range for that element. An element Cora has no reference range for carries the tag No Cora range. The report says how many elements have a Cora range and assesses the rest from general reef knowledge. Cora Assistant comments on every element that was tested, and its comment stands even when there's no Cora range.
If the lab prints n.d., or not detected, for an element, Cora records it as 0 and says it wasn't detected.
If a lab reports specific gravity (or relative density) instead of salinity, Cora stores it as salinity, still shown in SG, and grades it against your salinity range.
The Since your last ICP card shows what changed most since last time. It's usually the quickest way into a new report.
Tap Trends to see any element across every test you've uploaded. This is where ICP becomes really useful.
An RO/DI or source-water test
If you upload RO/DI or other source water, pick RO/DI water when you upload. Cora doesn't score it against your tank's targets. It gives a plain verdict on whether the water is clean enough to use, and it keeps those numbers out of your tank readings. It's saved as a separate report. Cora does the same for Salt mix or Other: it says what the sample looks like and doesn't score it as your tank.
Health reports
A Health Report is a deeper check of the whole system, done from time to time. It looks at every parameter, every source, your dosing, your history and your recent ICP results together.
Tap Health Report, then Generate. It usually takes about twenty seconds. Like ICP analysis, it needs Allow Cora Assistant to use saved tank data.
Use it when you want a careful look at the tank. Good times are before a big change, after a problem, or every few weeks as a check-in.
An open report has buttons at the top to export it as a PDF, share a snapshot of the tank, or delete it.
ICP against your probes
Cora compares your lab results with what your equipment reports. If your alkalinity probe says 8.4 and your ICP says 7.6, you'll want to know, and Cora shows you without quietly picking one.
This is one of the most useful things an ICP does in Cora. Treat it as a third opinion. It isn't the final word. Labs differ, and how a sample is handled, stored and shipped all move the result. A single ICP is evidence, and two tests that agree count for much more than one. If the gap persists, check the probe. It doesn't prove the probe is wrong.
Your allowance
Your plan sets how many ICP analyses and Health Reports you get each month. The line under the buttons shows what you've used. The numbers for each plan are in Plans and subscriptions.
When your ICP analyses are used up, Cora first shows the plans you can move to. If you'd rather not upgrade, it asks Save results without the AI analysis? Tap Save my results and Cora still reads the report and saves every value, so trends, history and your readings update as normal. The score and the written analysis stay locked. You can run them later from the report itself once you have an ICP analysis to spend.
On top of your plan's limit, Cora accepts up to 10 ICP uploads a day. An upload turned down for that reason doesn't use up any of your plan's ICP analyses. Cora Mobile only shows a general upload error, though, so if uploads start failing after a lot in one day, try again tomorrow.
Where reports live
The Intelligence screen keeps the two kinds apart. Lab results are under ICP REPORTS and generated reviews under HEALTH REPORTS. Each list shows the newest first, with its score. Tap one to open it again in full.
You can also get to them from Settings: open a tank, then ICP Reports or Health Reports.
Written for Cora Max 0.28.329 and Cora Mobile 1.4.30. Last checked 2026-10-17.
Still stuck? Email cora@coraiq.tech and we'll help.